Seitenansicht 17
Totalizer
Page
18
Chapter
07
Vögtlin Manual
red-y compact series
Version
compact_E4_0
Totalizer
General
The Totalizer function can be activated by the
manufacturer
.
Function
The instrument calculates the integrated value of the gas volume. The added up value is periodically
displayed and stored in intervals of 15 minutes in the non-volatile storage (EPROM). In the event of a
power disruption, the Totalizer therefore displays the correct total volume. It is, however, possible
that the gas volume for the past 15 minutes may be lost.
The added-up volume of the Totalizer and the flow value are alternatively displayed.
The display intervals are adjusted by the manufacturer as follows:
Flow: 5s
Total: 3s
The unit of the Totalizer volume is adjusted by the
manufacturer
.
Reset
The Totalizer function can be activated by the manufacturer in two different modes:
1. Totalizer without reset
In the event of a power disruption the most recently registered value from the non-volatile
storage (EEPROM) is loaded and added up further.
2. Totalizer with reset
In the event of a power disruption, the Totalizer volume is set to zero and from then on
resumes adding-up.
© Vögtlin Instruments AG