2.1 USE THE APPLIANCE FOR THE FIRST TIME
Before switching the appliance on please
familiarise yourself on how to isolate the appliance
from the electricity, gas, and water supplies. If in
doubt contact your installer.
2.2 USE THE MODE SELECTOR SWITCH
Turn the mode selector switch to the OFF position,
switch on the electrical supply to the appliance.
The green LED should be illuminated, you may
now select either HOT WATER ONLY or HEAT-
ING AND HOT WATER.
2.2.1 OBTAIN HOT WATER
By turning on a hot water outlet (tap) the boiler will
fire to deliver hot water.
The appliance will have been commissioned by
your installer to deliver hot water at both a
reasonable temperature and flow rate, should
you wish to increase the temperature of the hot
water simply reduce the flow of water as it comes
out of the tap. Please consult your installer for
further advice if required.
2.2.2 OBTAIN CENTRAL HEATING
When the time clock is in an ‘on’ position, and
the room thermostat – if fitted – is calling for heat,
the boiler will fire to provide central heating.
2.3 RE-PRESSURING THE SYSTEM
The system will need re-pressurising if the red
LED is illuminated. Locate the filling valve and if
necessary connect the loop (fig. 3) slowly open
the valve until you hear the water entering the
appliance. The red LED will go out first. Go on
with re-pressuring until the pressure shown on
the manometer is between 1 & 1.5 bar (fig. 4). The
appliance must not be operated until the system
has been re-pressurised. If in doubt contact your
installer.
2.4 SHUT DOWN THE SYSTEM FOR SHORT
PERIODS
The system can be shut down for short periods by
simply turning the mode selector to the OFF
position. It is also advisable to turn off the main
water supply to the house.
2.5 SHUT DOWN THE SYSTEM FOR LONG
PERIODS
If the house is to be left unoccupied for any length
of time – especially during the winter - the system
should be thoroughly drained of all water. The
gas should be turned off at the meter and the
main water supply should be turned off at the
stopcock. If necessary contact your installer for
further advice.
2.6 CARE FOR THE APPLIANCE
To clean the outer casing use only a clean damp
cloth. Do not use any scourers or abrasive
cleaners.
your installer may have adjusted this setting
during commissioning.
Please refer to the installation instructions for full
details.
1.4.3 ANTI-SEIZE FUNCTION
Should the appliance remain inactive for a period
of 24 hours, the pump will be activated for a few
seconds to prevent seizure.
1.4.4 APPLIANCE STATUS INDICATORS
The Vokera Compact has status indicators that
show if the appliance is working normally, if it
needs ‘topping up’ or re-pressurising, or if it has
a fault (see below).
1.5 GUARANTEE REGISTRATION CARD
Please take the time to fill out your guarantee
registration card. The completed warranty card
should be posted within 30 days of installation.
1.5.1
BENCHMARK
LOG BOOK
The
Benchmark
Log Book is supplied with your
boiler. This important document must be
completed during the installation/commissioning
of your boiler. All CORGI Registered Installers
carry a CORGI ID card, and have a registration
number.
Both should be recorded in your Benchmark Log
Book. You can check your installer by calling
CORGI direct on 01256 372300.
Failure to install and commission the appliance in
accordance with the manufacturers instructions
may invalidate the warranty. This does not affect
your statutory rights .
Fig. 3
control valve
temporary
connection
control valve
supply pipe
double check
valve
flow/return
pipe
Fig. 4
correct
pressure value
Seitenansicht 3
1 2 3 4 5 6 7 8